pv-calor.com

Air-to-Air Heat Pump Calculator

Calculate split air conditioners for heating and cooling according to EN 14825

Quick Start

What does this calculator compute?

The air-to-air heat pump calculator sizes split air conditioners for heating and cooling. These systems are ideal as a supplement to existing heating or for full supply of individual rooms.

Use cases:

  • Single-Split: One outdoor unit + one indoor unit for one room
  • Multi-Split: One outdoor unit + multiple indoor units for different rooms
  • Bivalent operation: Combination with existing heating (gas, oil, pellets)

Calculation basis

The calculator is based on:

  • EN 14825:2022: SCOP/SEER calculation for heat pumps
  • VDI 4650: Annual performance factor for Germany/Austria
  • Climate zones: Average (Central Europe), Warmer (Southern Europe), Colder (Northern Europe)

Input parameters

Outdoor unit

  • Rated heating capacity: Power at 7°C outdoor temperature
  • COP values: At various outdoor temperatures (A7, A2, A-7, A-15)
  • SCOP/SEER: Manufacturer data for seasonal efficiency
  • Minimum operating temperature: Important for cold winters

Indoor units

  • Type: Wall unit, console, cassette, ducted
  • Rated capacity: Heating and cooling power
  • Room assignment: For multi-split systems

Bivalent operation

  • Bivalence point: Temperature at which existing heating takes over
  • Operating mode: Alternative, parallel or partial parallel
  • Daytime operation: Optional daytime only (noise protection)

Results

  • SCOP/SEER: Seasonal efficiency for heating/cooling
  • Power consumption: Annual consumption in kWh
  • Load profile: Hourly power consumption for PV integration
  • Economics: Payback, savings vs. existing heating

Advantages of air-to-air heat pumps

Compared to conventional heating:

  • High efficiency (COP 3-5)
  • Heating AND cooling in one device
  • Quick installation without water connection
  • Room-by-room temperature control

For PV systems:

  • Ideal addition for self-consumption
  • Cooling in summer uses PV surplus
  • Load profile export for solar calculator integration

Next step: With the Solar Calculator you can cover the power consumption of your air-to-air heat pump with a PV system.