Renovation Recommendations from Heating Load Calculation - Summary

A heating load calculation is more than just a number for heating system sizing – it's an X-ray of your building. The detailed results show exactly where heat is lost and where renovation measures have the greatest effect.

Understanding the Building Envelope

Heat escapes in three ways:

  • Transmission: 70-85% (through walls, windows, roof, floor)
  • Ventilation: 15-25% (air exchange, leaks)
  • Thermal bridges: 5-15% (connections, penetrations)

The Most Important Renovation Measures

Measure Savings Cost/m² Payback
Top floor ceiling insulation 10-15% 30-60 € 3-6 years
Basement ceiling insulation 5-10% 35-55 € 5-8 years
External wall insulation 20-35% 120-180 € 12-20 years
Window replacement 10-15% 400-600 € 15-25 years

The Golden Rule

"First the envelope, then the technology!" Renovate the building envelope first, then the heating system. An optimally insulated building envelope needs a much smaller (and cheaper) heating system.